Hood Exhaust CFM Table *CFM / lineal ft. of hood front 1) Extra heavy-duty cooking appliances (non-canopy hood not allowed) 550 Type I hood e.g. Specify the types of materials and sheen (e.g., semi-gloss only). The following resources are intended to assist applicants in obtaining permits or information about different permit requirements and/or processes. The piece of equipment that is located at the end of the exhaust hood will have the greatest impact on the hood's overall effectiveness. A valve shall be located on the main gas line feeding the * Must sit at least 18 inches above the stove. Transporting food - this is particularly important for food delivery kitchens. Section 1106Machinery room, special requirements. Hood height, accessories and material gauge affect overall hood weight. HTML PDF: 51-52-1107: Section 1107Reserved. Hood joints, seams and penetrations meet criteria 3. You can find more detailed information about your state's requirements here. For an over-the-range microwave, the height from the stovetop doesn't necessarily matter since there is no flame. These rules are the standards with which food establishments must comply in the handling, storing, preparation and service of food to the retail food consumer. For the professional gas cooking ranges, the most common range hood is the 18" canopy wall hood. Please consult your local Building Code Office to see if they require more overhang. An audible alarm or visible indicator shall be provided. Larger hoods will have additional brackets. Commercial kitchen exhaust hoods shall comply with the requirements of this sub rule and NFPA 96-2014. 2. For example, a 100,000 BTU stove needs at least a 1000 CFM range hood. Leave this document with the owner when installation or service is complete. Kitchen ventilation typically is provided by a vent hood (also called a range hood) or by an above-the-counter microwave with an integrated vent fan. effluent and are shorter in front tapered height and width than a canopy hood. Sections 507.2 to 507.6.1. Some typical restaurant vent hood requirements include: Must be constructed of at least 1.181 mm steel or 0.8525 mm stainless steel. 18-28-702.1 Unconfined spaces. Cooking equipment involving solid fuels, vegetable or animal oils and fats must be protected by a Class K portable extinguisher. Protective shield plates shall be constructed of steel, shall have a minimum thickness of .062-inch (1.6 mm) and shall extend not less than 2 inches (51 mm) above sole plates and below top plates. To find the fan needed for your size kitchen, multiply the number of cubic feet in the room by the number of air exchanges (15), then divide by the number of minutes in an hour (60). NFPA 11.6.1: "Upon inspection, if the exhaust system is found to be contaminated with deposits from grease-laden vapors, the contaminated portions of the exhaust system shall be . However, certain requirements must be met, including: These same requirements apply for systems with standing or electronic pilot ignitions. 10. Type II Hood. Place your low-duty equipment at the end of the cook line and position the heavy-duty equipment in the center of the cook line to optimize hood performance. The Minnesota Food Code, Minnesota Rules Chapter 4626, contains the minimum design, installation, construction, operation and maintenance requirements for all food establishments in Minnesota. Section 506Commercial kitchen hood ventilation system ducts and exhaust equipment. Standard NFPA 17A : Wet-chemical extinguishing systems Testing Four different commerical kitchen and dishwasher exhaust hood solutions available DELTA - 1500 1500mm depth suitable to capture and contain combination steam ovens Requires a minimum 2700mm floor to ceiling height for installation DELTA - B Type Suitable to capture and contain standard cookline equipment - max depth 900mm If fire alarm system is installed in building, it shall be activated. B33 - Fire Damage; B36 - Garage / Accessory Structure; B37 - Clearing, Fill and Grade; B41 - Building . Manufacture commercial kitchen hood exhaust system to specifications of your place and food establishment menu. . While most states and municipalities follow the International Mechanical Code as the basis for their regulations, certain specifications and code requirements can vary depending on where you live. ceiling, wall or furred space it shall be enclosed from the point of penetration to the outlet . Be airtight. 8.1 Exhaust Fans for Commercial Cooking Equipment 8.1.1.3 Upblast fans shall have a drain directed to a readily accessible and visible grease receptacle not to exceed 3.8 L (1 gal). 2. The ventilation system comes in stainless steel with hood, filter, fans, duct. Standard Z9.5 recommends a minimum stack height of 10 ft above the adjacent roof line, an exhaust velocity V e of 3000 fpm, and a stack height extending one stack diameter above any architectural screen; National Fire Protection Association (NFPA) Standard 45 specifies a minimum stack height of 10 ft to protect rooftop work-ers. State and Local Regulations State and local governments have their own sets of requirements for commercial kitchens you must familiarize yourself with during the design and building processes, as they may be different than those at the federal level. The commercial kitchen must have at least 5 of the following items: multi-plate cook top; oven/s with capacity greater than 60L Some highlights that relate to a commercial kitchen are: Your kitchen will need a hand sink that's only for hand washing Your refrigerator must be below four degrees Celsius at all times Your freezer must be below 18 degrees Celsius at all times All your food inventory and utensils need to be at least six inches from the floor 506.2 Corrosion protection. * Must be supported by non-combustible materials. Subp. All commercial kitchens must register with the state and apply for a business license from their local municipality. Scenario 2 - Overhead clearance rates not specified on installation instructions. Elevations, including building height Commercial Building Elevations per KCC 17.382.030, 17.382.070 footnotes 5 & 25, The objective of this Standard is to ensure that, where possible, the layout of the premises All Target canopy exhaust hoods are manufactured in accordance to BESA DW/172 second edition 2018 specification for commercial kitchen ventilation systems. Each required commercial kitchen exhaust hood and duct system required by Section 609 to have a Type I hood shall be protected with an approved automatic fire-extinguishing system installed in accordance with this code. 30,720 cubic feet 60 minutes = 512 CFM range hood fan or higher. Electronic Controls: Remote Control If the hood has electronic controls, it may offer the options of either a wall mounted or handheld control that meets ADA's grasp and force requirements. For safety reasons, the NFPA (National Fire Protection Agency) has additional installation requirement for commercial kitchen applications. A minimum of four 8" long mounting angles or two 8" long and full length mounting angle, depending on hood type, are provided with each hood. Type II hood materials shall be constructed of stainless steel not less than 0.024 inch (0.61 mm) (No. The design of the plumbing systems in a commercial kitchen is almost as complex as a hospital, but without the critical life support systems. For example: 2,048 cubic foot room x 15 air exchanges = 30,720 cubic feet moved per hour. For electric stoves, multiply the stove width by 10. between the gyp board and the hood. Cleanup/prep and sink placement The effect of this rule is to prevent the refrigerator or stove being installed along the same wall as the sink. Show/note all cooking equipment that must be provided with a Type 1 hood. The general requirements of the International Residential Code (IRC-M1503.1 and .2) for range hoods are: Must discharge to the outdoors (not terminate in attic). . Designed, manufactured and installed to suit individual requirements Target's commercial kitchen exhaust hoods are available as an individual unit or as part of a complete ventilation system. Understanding basic HVAC Design for Commercial Kitchens Basically, Heating, ventilating and air conditioning (HVAC) refers to simultaneous control of temperature, humidity, radiant energy, air motion and air quality. areas of the building requirements, including equipment sizing Provide stock storage height and type . According to a recent poll, which surveyed more than 700 restaurants in the United States, the average size of a commercial kitchen is 1,051 square feet. T -Tapered Hood Front face 6", Front and Rear of Equal Height, ranging from 18" - 24" BS -Backshelf Front down to 0", Rear 42" Tall 3 Save these instructions. WARNING! Proximity (Backshelf) Hoods Single . o kitchen hoods o other conveying systems . Because the manufacturer's specification for the range specifies this hood, builders are bound by best practice and essentially by code to follow the specification. 18-28-506 Commercial kitchen grease ducts and exhaust equipment. 12. NFPA 96 serves to outline how often your vent hood system should be cleaned by a certified professional, as well as the guidelines of what areas need to be cleaned. This material shall extend 18" minimum beyond all sides or edges of the hood. D. Type of hood: (507.2) 1. ! This requirement applies even if you run the kitchen from your personal residence . But, they can be classified into ducted and ductless depending on their ventilation. Exceptions: 18-28-507.1 General. Example 1 IMPERIAL Hood Model GHEP Hood Weight Equation (lb) Hood Length 60 inches (5 ft) Base Weight (lbs) + [ Length (ft) x Weight per Length (lbs/ft) ] = Hood Weight (lbs) Hood Depth 24 inches (2 ft) 28 lbs/ft + (5 ft x 20.4 lbs/ft) = 130 lbs Example 2 METRIC After the acquisition of the hood, you should proceed and install it around 20'' to 24'' inches just above the cooktop. Issue: 8/01. 2015 Michigan Mechanical Code > 5 Exhaust Systems > 507 Commercial Kitchen Hoods > 507.1 General 2. A different kind of range hood for professional gas cooking ranges is the vent hood insert/liner. commercial kitchen hood ventilation system ducts and exhaust equipment shall comply with the requirements of the International Mechanical Code. Information about kitchen equipment and ventilation requirements may evolve over the course of the design phase. 0.5kW/M 2 (1.8MJ/M for gas appliances) of total floor area of the kitchen; or (d) the local government body deems the installation of a kitchen exhaust hood to be appropriate due to the circumstances. C. Commercial Kitchen Hood 1. (The submittal drawings indicate the location of these brackets to enable the contractor to make preliminary plans for hanging the hoods.) Commercial Kitchen Hoods (Types 1 + 2) Design Guidance. Pre-engineered fire suppression systems shall be installed only by companies and individuals licensed by minimum rating of 40-B shall be installed at an approved location, and within 30 feet of commercial food heat-processing equipment, as measured along an unobstructed path of travel. Large gas ranges often "require" a large, high CFM hood. hood requires a shaft, as well as make-up air. (IFC 904.12.5, IBC 906.4) a. Commercial kitchen hood ventilation ducts and exhaust equipment shall comply with the requirements of this section. 1003.3.1 Headroom. Provide a heat sensor or other device to insure the automatic operation of both the kitchen hood and the makeup air systems upon activation of the cooking devices. The State's minimum requirements for fire suppression systems for commercial cooking equipment shall be established by the Life Safety Code and NFPA 96. Besides, it will ensure that your restaurant kitchen has fresh and cleaner air. hoods and exhaust systems shall be permitted to vent gas-fired equipment installed in commercial applications. 4. This document is the property of the owner of the equipment. There are three core areas of food hygiene in a commercial kitchen: Personal hygiene - this includes proper hand washing, sickness rules and clothing requirements like hair nets. Use of Ventilated Roof Curb Use of Grease Collector Use of Clean-out Port Use of Hinge Kit Roof deck to top of exhaust fan windband - 40" min. For electric cooking, a range hood should be between 24-32 inches from the stovetop to the bottom of the hood. The equipment must be commercial-grade and appropriate to the range of food proposed by the applicant. For 36-inch high counters, a minimum 15-inch deep clear knee space for each seated diner. The kitchen must also comply with food and hygiene regulations. 2. a "hood". equipment schedules. This is a lot of air for a house, especially a new, tight . Where the manufacturers of the gas cooking appliance and the rangehood / exhaust fan do not specify a minimum clearance rate, then the practitioner must provide a clearance rate of no less than 600mm for a rangehood and no less than 750mm for an exhaust fan, in accordance with AS/NZS 5601.1 Clause 6.10.1.1 (a). Successful application of the fundamentals of commercial kitchen ventilation during the design process requires a good grasp of your local building code requirements, menu and appliance preferences, and project budget. * All exterior joints must be welded. over enclosure and flue bypass to meet your design requirements. For grease and smoke removal: Type I _____Quantity Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code. Food storage - this covers the ways that raw, cooked, hot and cold food are stored. Such hoods are equipped with a fire suppression system. Start cooking up something delicious on your stovetop and the ZLINE 30-inch Range Hood will remove airborne grease, fumes, smoke, heat, and steam from the air through the . For 42-inch high counters, a minimum 12-inch deep clear knee space for each seated diner. The size of this is dependent on the equipment (as Pete says, the menu dictates the equipment). (SMC requires it to be from 10-20 feet of hood.) This document is the property of the owner of the equipment. In addition to that, control of pressure in the conditioned space relative to adjacent areas is a requirement. Light reflects off walls, ceilings, floors and surfaces. See IMC 507.1. Recommended mounting height from bottom edge of hood to the finished floor is 6'-6", (18" -24" from bottom edge of filter to cooking surface for Back Shelf type models). Overall, kitchen hood installation is an important task in commercial kitchen ventilation systems. UL listing for the Type 1 kitchen grease hoods to be installed. There are many types of kitchen exhaust hoods in the market. See IMC 507.1.1. Keeping your commercial kitchen hood clean and well-maintained will ensure that your staff along with your entire facility is protected against any fire-hazards but also reduces the risk of personal liability in the event of a fire or suppression . Most states require commercial kitchens to apply for a sales tax license and file periodic tax returns. Applicant shall provide plan and elevation views showing ductwork, duct enclosure, hood, cooking surface air supply, exhaust system, and equipment support including structural detail (See attached examples 1,2 and 3). So, for a 42" electric stove you want a range hood with at least 420 CFM. [M] 607.2 Where Required A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. 10. how the location of the Type 1 hood in S relation to the kitchen ceiling and walls. 1. 24 Gage) in thickness, copper sheets weighing not less than 24 ounces per square foot (7.3 kg/m 2 ), or of other approved material and gage. However, if it is being placed above a gas range, the distance should roughly be between 25'' to 30'' unless . HOOD.An air intake device used to capture by entrapment, impingement, adhesion or similar means, grease, moisture, heat and similar contaminants before they enter a duct system. 2. To legally operate your kitchen, you must adhere to local commercial kitchen hood code requirements. Commercial kitchen equipment for commercial hotels. To determine the correct size Grease Range Hood System to install, National Fire Code (NFC) dictates that the Hood should be 6 inches larger on all sides compared to all of the equipment that is under it. Dessert presentations and cake decorating require 400-800 lux. The inside lower edge of canopy-type commercial cooking hoods shall overhang or extend a horizontal distance of not less than 6 inches (152 mm) beyond the edge of the cooking surface, on all open sides. Broan-NuTone 422401D Range Hood. 2 . Complete and return a Hood Worksheet for each ventilation system. Meanwhile, for induction cooking, the hood should be anywhere from 28-36 inches above the cooktop. Have a smooth interior surface. This Standard sets out requirements for food premises and equipment that, if complied with, will facilitate compliance by food businesses with the food safety requirements of Standard 3.2.2 (Food Safety Practices and General Requirements). Minimum hood metal thickness 18 ga. (0.046") for steel; 20 ga. (0.033") for stainless steel for Type I, Minimum hood metal thickness 22 ga. (0.029") for steel; 24 ga. (0.022") for stainless steel, or other approved material for Type II 2. HTML PDF: . 18-28-507 Commercial kitchen hoods. NFPA 96 simply states in Chapter 5.2 Hood Size, "hoods shall be sized and configured to provide for the capture and removal of grease laden vapors." This coincides with Chapter 8.2.2. on Air Volume which states "Exhaust air volumes for hoods shall be of a sufficient level to provide for capture and removal of grease laden cooking vapors" Finish schedule for walls, floors, and ceilings in each room or area, including inside walk-in refrigerator and freezer units. This is a design review checklist for code requirements for commercial kitchen hoods including grease ducts and their connections to hood and roof exhaust fans, exhaust fan details, make-up air details and suppression . provided within a 30-foot travel distance from commercial cooking equipment. Cooking surfaces (cooktop or range top) must be ventilated by a hooded fan rated for at least 100 cubic feet per minute (cfm). Measure the width of the area over the range or cooktop. 18-28-702 Air requirements for equipment located in unconfined spaces. The hood should be at least as wide as the cooking surface, but preferably should be 6" wider. . You can apply by mail, online or by phone. Type I Hood.A kitchen hood for collecting and removing grease vapors and smoke. Hoods shall be Type I or Type II and shall . The recommended illuminance level for a commercial kitchen's general working area is 160 lux. 2018 International Building and Mechanical Code and Commentaries. All solid-fuel including solid-fuel pizza oven. When it comes to creating the layout of your kitchen, however, this may be more of a fun . HTML PDF: 51-52-1400: Chapter 14 . Commercial kitchens come in many sizes and shapes from small restaurant or deli kitchens to large commercial kitchens preparing thousands of meals at a time. How to Place Equipment Under a Kitchen Hood. Rewiring a hood could invalidate the warranty unless the manufacturer has provisions for this option. Hoods should be hung level, and where possible, the exhaust outlet should be in line with the exhaust fan opening. Manufacturers include the specific height for the range hood in the instructions that come with it. This type of range hood should be installed at the height of 30" to 36" above the cooktop. LBOX/LBMUA -Low Box Hood/Low Box Make-Up Air Front as low as 6", Rear ranging from 18" - 24" T -Tapered Hood Front face 6", Front and Rear of Equal Height, ranging from 18" - 24" BS -Backshelf Front down to 0", Rear 42" Tall 3 Save these instructions. For food preparation, cooking and washing areas the luminance should be 240 lux. You won't really be able to test this in your own kitchen. If any portion of the hood penetrates the . Step 2: Measure the width of the area between the cabinets. A "K" Class fire extinguisher will also be required. * Must extend at least 6 inches past all open edges of the stove. Roof deck to top of curb - 18" min. Commercial Kitchen Ventilation Hoods, Filters, External Supply Plenums and Accessories August 2020. The "heart", so to speak, of the kitchen isn't really the stove, but rather the ventilation system, a.k.a. Commercial kitchens are one of the most challenging designs a plumbing engineer will ever face. Saturday, January 2, 2021. 10. Mise Designs 1530 North Main Street Williamstown, New Jersey 08094 (856) 885-4675 2007-2022 See the handout, Requirements for Hood Plans, for complete details. HTML PDF: 51-52-1200: Chapter 12Hydronic piping. Commercial kitchen grease ducts shall be designed for the type of cooking appliance and hood served. This can serve as a guide for some operations, but there are other metrics that may prove more useful. Types of Kitchen Hoods. NFPA 96 Hood Cleaning Frequency Summary: You are required to have your exhaust system cleaned at the frequency shown below. 4.0 APPROVAL (1) Prior to the fabrication and installation of any kitchen exhaust system in a food premises, plans and specifications must be . The commercial kitchen, however, provides a more exotic array of fixtures and equipment, such as preparation and triple-compartment sinks, large dishwashers, food waste grinders and disposals, hose sprays, soda dispensing systems, wash down hoods, icemakers, and . Medium-duty cooking appliances 300 wok, broiler (gas or electric), gas burner range. 2. Drains for equipment are sometimes located when the floor is poured, or block outs can be left for later installation. HTML PDF: 51-52-0507: Section 507Commercial kitchen hoods. Range hoods shall discharge to the outdoors through a duct. Mechanical Commercial Kitchen Hood; B17a - Mechanical Kitchen Type 1 Hood Suppression . 3. This specific requirement is more relevant for electric stoves in commercial kitchens. 3. To power your range hood, you need at least 100 CFM for every 10,000 BTUs of your stovetop. Heavy-duty cooking appliances 400 Type I hood e.g. NFPA 96 Hood Requirements Published by Kitchen_2020 on September 23, 2019 September 23, 2019. . We hope this commercial kitchen hood exhaust . The vertical distance between the front lower lip of the hood and the cooking surface shall not exceed 4 feet (1219 mm). SECTIONM1503 RANGE HOODS ES M1503.1 General. Range hoods often come in 24", 30" or 36" widths. The name "proximity" refers to the close proximity . It's not uncommon to see hoods rated from 600 to 1200 CFM. A range hood is required for an electric stove if the stove produces less than 5 micrograms of grease when tested at 500 CFM. For example, if you have a 36" wide, 6-eye Range, 24 . All solid fuel cooking appliances, whether or not under a hood, with fire boxes 5 cubic feet or